3-13
Boonton Electronics Chapter 3
4530 Series RF Power Meter Operation
3.8.4 Parameter Editing. The and keys are used to increment or decrement the value of the currently selected
edit parameter. The increment and decrement intervals are preset, although their values may change depend-
ing on current settings. Note that key repeat is active, and holding the key will cause the parameter to
continue to advance. See the “Key Repeat” section above for tips on most effective use of the auto-repeat
feature.
Note that if a specific value that is considerably different from the current value of the parameter is desired,
it may be more convenient to enter Menu Mode, and edit the parameter using digit editing mode rather than
try to increment or decrement a long distance to the new value.
Channel Edit Parameter List
Selected Parameter and Current Value
Figure 3-14. Edit Mode Operation (Example)
Table 3-2. Graph and Text Mode Edit Menus
Meas Mode Edit Menu Parameters / Values
Freq* Units Resoltn Filter Ld/ClrR DutyCyc Offset
CW 0.01 to
(Text) 1 to 3 None, Auto,
to Ld Ref 100.00% -100.00dB
to
0.001 to dBm significant 0.01 to
to Clr Ref PeakHld +100.00dB
M
odulated 110.00 GHz Watts digits 15.00 sec Off, InstHld
(Text) Volts AvgHold
* Impedance dBV TimeSpn TrigDly TrigLvl Marker1 Marker2
Pulse for voltage dBmV 2.5µS to TimeSpan -40dBm to Trace start to trace end
(Text) sensors: dBuV 5 seconds Dependent +20dBm in display window
50-2500 StatMode TermCnt MarkrMod Marker1 Marker2
Statistical CDF, 1-CDF, 2M to Off, Vertical, Vert: 0.000 to 100.000%
(Text) Distribution 4000M Horizontal Horz: -99.99 to +99.99dBm
VertSpn VertCtr TimeSpan Filter Ld/ClrR DutyCyc Offset
CW 0.01 to
(Graph) Log Scaling: Log Scaling: 1 second None, Auto,
to Ld Ref 100.00% -100.00dB
to
0.1dB to -100dBm to to 1 hour 0.01 to
to Clr Ref PeakHld +100.00dB
M
odulated 100dB +100dBm 15.00 sec Off, InstHld
(Graph) AvgHold
Linear Scaling: Linear Scaling: TimeSpn TrigDly TrigLvl Marker1 Marker2
Pulse 1nW to (VertSpan 2.5µS to TimeSpan -40dBm to Trace start to trace end
(Graph) 1MW dependent) 5 seconds Dependent +20dBm in display window
HorzSpn %Offset MarkrMod Marker1 Marker2
Statistical 1 to 100% HorzSpan Off, Vertical, Vert: 0.000 to 100.000%
(Graph) Dependent Horizontal Horz: -99.99 to +99.99dBm