Boonton 52000 Series USB CW Power Sensor Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Boonton 52000 Series USB CW Power Sensor. Boonton 52000 Series USB CW Power Sensor User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
User’s Guide
52000 Series USB Power Sensor/Meter
Taking performance to a new peak
Przeglądanie stron 0
1 2 3 4 5 6 ... 67 68

Podsumowanie treści

Strona 1 - User’s Guide

User’s Guide52000 Series USB Power Sensor/MeterTaking performance to a new peak

Strona 2 - Safety Notices

10 Software InstallationFigure 2 Start of installation software4 Check the software matches your sensor types and then select Continue The sensor par

Strona 3 - Key Features

Boonton 52000 Series 11Figure 4 License agreement6 Choose the installation location, whether you want a desktop icon and a shortcut added to your sta

Strona 4 - What you should have

12 Software InstallationFigure 6 Installation completedNote At the end of the installation you are asked to connect your sensor. Refer to “USB Instal

Strona 5 - Contents

Boonton 52000 Series 132 USB InstallationThis chapter explains the process for installing and enabling the USB drivers for your 52000 series CW power

Strona 6 - Contact And Support

14 USB InstallationFigure 7 Windows hardware installation wizard3. Choose “Install from a list or specic location (Advanced)” and select Next.Refer

Strona 7 - Safety And Specications

Boonton 52000 Series 154. Choose “Include this location in the search”. Refer to Figure 9 on page 15.Figure 9 Choose the installation location5. Brow

Strona 8 - 8 Installation

16 USB InstallationThe USB driver that is installed is a generic USB sensor driver and it is used for a range of USB sensors. The sensor driver insta

Strona 9 - 1 Installation Of Software

Boonton 52000 Series 171. Connect your sensor to the USB port of your PC. The Windows Hardware Wizard starts automatically. Refer to “How to connect

Strona 10 - 10 Software Installation

18 USB InstallationFigure 12 USB Driver location4. Choose “Include this location in the search”. Refer to Figure 9 on page15.Figure 13 Choose the ins

Strona 11 - Boonton 52000 Series 11

Boonton 52000 Series 195. Browse to the following location: C:\ProgramFiles\Boonton\Driver.If you have changed the default installation location, nav

Strona 12 - 12 Software Installation

2 IntroductionNotices© BOONTON (A WIRELESS TELECOM GROUP COMPANY) 2006 This document contains information which is protected by copyright. Reproducti

Strona 13 - 2 USB Installation

20 USB InstallationThis page is intentionally left blank

Strona 14 - 14 USB Installation

Boonton 52000 Series 213 Hardware ConnectionsThis chapter provides an overview of how to connect your 52000 CW power sensor/meter in your test enviro

Strona 15 - Boonton 52000 Series 15

22 Hardware ConnectionsConnection to your unit under test (UUT)The 52000 series CW power sensor/meter has a standard SMA-m connection port.The recomm

Strona 16 - 16 USB Installation

Boonton 52000 Series 23Connecting multiple sensorsIt is possible to connect and monitor multiple sensors. The number of sensors you can connect to yo

Strona 17 - Boonton 52000 Series 17

24 Hardware ConnectionsThis page is intentionally left blank

Strona 18 - 18 USB Installation

Boonton 52000 Series 254 Using The SoftwareThis chapter describes how to use the Boonton software when making typical power measurements. It also pro

Strona 19 - Boonton 52000 Series 19

26 Using the SoftwareWhen the software is started, measurement results are displayed right away. However you are reminded that you should zero the se

Strona 20 - 20 USB Installation

Boonton 52000 Series 27Figure 19 Control panel3. Choose Log Power from the measurement mode section of the control panel dialog box.Top left corner o

Strona 21 - 3 Hardware Connections

28 Using the Software5. Choose Use Table in the calibration factor section of the control dialog box. This uses the sensor’s internal calibration tab

Strona 22 - 22 Hardware Connections

Boonton 52000 Series 291. Connect all your sensors to your PC.2. Double-click on the desktop icon for the Boonton software.3. To identify which senso

Strona 23 - Connecting multiple sensors

Boonton 52000 Series 3User’s GuideWelcome Thank you for choosing the 52000 Series USB Power Sensors/Meter and welcome to the Boonton User’s Guide.Thi

Strona 24 - 24 Hardware Connections

30 Using the SoftwareHow to make a pulse power measurementThe following procedure outlines how to set up and make a pulse power measurement. For mor

Strona 25 - 4 Using The Software

Boonton 52000 Series 31pulse periodon timetimepulse poweraveragepowerduty cycle = on timepulse period100%1p.r.f. =pulse periodaverage power = on time

Strona 26 - Making a measurement

32 Using the Software8 123 456 7 81TB3Data5757DataTraining26f1f1TB3GB8.251 TDMA frame (4.615 ms)1 timeslot (0.577 ms)TB = Tail Bitsf = FlagGB = Guard

Strona 27 - Boonton 52000 Series 27

Boonton 52000 Series 33Measuring power greater than +20dBm (100mW)The offset facility is useful when an attenuator or amplier is used ahead of the s

Strona 28 - 28 Using the Software

34 Using the SoftwareFigure 28 Sensor conguration using an attenuatorMeasuring an attenuator using relative modeUse relative mode to measure an atte

Strona 29 - Boonton 52000 Series 29

Boonton 52000 Series 35Figure 29 Enable relative measurement mode6. Select the Set button. The display should be 0.000 dB.7. Remove the attenuator an

Strona 30 - 30 Using the Software

36 Using the Software3. Set the measurement frequency. This is set in the measurement control panel.4. In the measurment control panel, enable the li

Strona 31 - Measuring GSM mobile signals

Boonton 52000 Series 37Figure 31 Low limits warning messageIf the level rise above 4dBm then a high limit warning message will appear. Refer to Figur

Strona 32 - 32 Using the Software

38 Using the SoftwareHow to use trace modeThe trace facility is useful for plotting the level being measured by the sensor over a period of time. To

Strona 33 - Boonton 52000 Series 33

Boonton 52000 Series 394. Set the plot scaling to Auto. The Y-axis is automatically scaled to suit the Min and Max valuesassociated with the level be

Strona 34 - 34 Using the Software

4 IntroductionWhat you should haveBefore you start, please check you have the following items (Refer to Figure 1 “What you should have” on page 4):•

Strona 35 - How to use measurement limits

40 Using the SoftwareFigure 35 Trace controls dialog boxWhen the trace is complete, markers for making X and Y measurements can be turned on by selec

Strona 36 - 36 Using the Software

Boonton 52000 Series 41Figure 36 Trace markersThe displayed trace can be saved by selecting the File > Save Trace in the trace control dialog box

Strona 37 - Boonton 52000 Series 37

42 Using the SoftwareError and status messagesThe right side of the users interface displays a series of warnings and status messages. These are desc

Strona 38 - How to use trace mode

Boonton 52000 Series 43Sensor overloadThis warning message indicates a sensor overload. Refer to Figure 38 on page 43.Figure 38 Sensor overload warni

Strona 39 - Boonton 52000 Series 39

44 Using the SoftwareLow limit exceededThis warning message tells you when you have exceeded the low measurement limit you have set in the measuremen

Strona 40 - 40 Using the Software

Boonton 52000 Series 45Manually entered cal factorWhen you have entered a cal table, the entries are displayed on the user interface. Refer to on pag

Strona 41 - Boonton 52000 Series 41

46 Description of Software5 Description of SoftwareThe following section describes the basic software features. For more information on the software

Strona 42 - Error and status messages

Boonton 52000 Series 47Description of menu optionsThe following describes the menu options from the application.File MenuSave SetupAllows current set

Strona 43 - High limit exceeded

48 Description of SoftwareCalculatorsThis menu option gives you access to three useful microwave calculators.These are:• VSWR Mismatch• Parameters• P

Strona 44 - Low limit exceeded

Boonton 52000 Series 496 Enhanced Features This chapter outlines the advanced capabilities of the 52000 series CW power sensor/meter software.There

Strona 45 - Manually entered cal factor

Boonton 52000 Series 5 ContentsIntroduction ...3Key Feature

Strona 46 - 5 Description of Software

50 Enhanced FeaturesThe le USB Sensor Lib.dll can reside in the same directory as your application executable le, or in a path known to your applic

Strona 47 - Tools Menu

Boonton 52000 Series 517 TroubleshootingThis chapter explains how to x some typical software and hardware conguration issues that you may have enco

Strona 48 - Help Menu

52 TroubleshootingNo sensor is attached to your PCCheck all cable connections from your PC to your sensor. A connector may have been loosened and may

Strona 49 - 6 Enhanced Features

Boonton 52000 Series 53If this is NOT the driver listed in your Device Manager, then use the following procedure to remove the installed driver and c

Strona 50 - 50 Enhanced Features

54 TroubleshootingMore than one application has been startedIt is possible to start multiple instances of the application software. The rst time the

Strona 51 - 7 Troubleshooting

Boonton 52000 Series 55How to identify your PC operating systemThe procedure for installing USB drivers differs slightly depending on which version o

Strona 52 - 52 Troubleshooting

56 Other InformationOther useful informationThe following sections provide some useful information about power measurement and your USB sensor.What i

Strona 53 - Incorrectly congured USB hub

Boonton 52000 Series 57The RF in the burst is also assumed to be un-modulated. If it were amplitude modulated, for example, then the measurements wou

Strona 54

58 Other InformationWhat is a dBm?When one of the powers is dened, again for convenience, as 1mW, then the related unit, abbreviated to ‘dBm’, is de

Strona 55 - Boonton 52000 Series 55

Boonton 52000 Series 598 Contact and SupportThis chapter provides information about Boonton. It tells you how to get in touch and what to do if you a

Strona 56 - What is zeroing?

6 ContentsMeasuring GSM mobile signals ... 31Making a measurement ...

Strona 57 - What is a dB?

60 Safety & Specications9 Safety and SpecicationsThis chapter provides information about the 52000 Series CW power sensor/meter safety complian

Strona 58 - What is a dBm?

Boonton 52000 Series 61

Strona 59 - 8 Contact and Support

62 Safety & SpecicationsWEEE DirectiveBoonton will undertake a “take back” policy for all sensor products no longer t for purpose and dispose o

Strona 60 - 9 Safety and Specications

Boonton 52000 Series 6352012Frequency 10MHz to 12.4GHzMeasurement range -50 to +20dBm CW Operating Temperature 0 to 50 deg CShock 25G, 11 msVibrati

Strona 61 - Boonton 52000 Series 61

64 Safety & Specications52018Frequency 10MHz to 18.5GHzMeasurement range -50 to +20dBm CWOperating Temperature 0 to 50 deg CShock 25G, 11 msVi

Strona 62

Boonton 52000 Series 65IndexAAttenuator ... 33

Strona 63 - Boonton 52000 Series 63

66 Indexhelp menu ... 48high limit ...

Strona 64

Boonton 52000 Series 67pulse measurement ... 30, 56Rreturn products

Strona 65 - Boonton 52000 Series 65

Boonton Electronics25 Eastmans Rd.Parsippany, NJ 07054U.S.ATel. +1 973 386 9696Fax. +1 973 386 [email protected]© Copyright 2006B

Strona 66 - 66 Index

Boonton 52000 Series 7Safety And SpecicationsSafety notices ... 6

Strona 67 - Boonton 52000 Series 67

8 InstallationThis page is intentionally left blank

Strona 68 - © Copyright 2006

Boonton 52000 Series 91 Installation Of SoftwareThis chapter provides information about installing the Boonton power sensor/meter software.Before you