PIM31 Remote Setup and Operational Procedures
1 Remote Application and TCP/IP Setup
PIM31 Remote Control Panel is the software to control the PIM31 unit from any PC
using a TCP/IP cable connection. This section explains how to setup the PIM31 unit
for TCP/IP from any PC and also the use of the remote application. The software can
be downloaded from the Boonton official website under Products “Manuals & Software”.
1.1 Installation and connection setup for remote control:
1.1.1 Install PIM31 Remote Software
Download the PIM31 Remote Control software from Boonton’s official website
under product’s Manuals & Software” section
Follow screen instructions during the installation process
Click on “Remote_ctr_V1.2.exe” icon from PC’s desktop to open the software.
1.1.2 Known issues that might occur during installation on Windows OS:
Error message as “Component MSWINSCK.OCX or one of its dependencies not
correctly registered: a file missing or invalid.
If you do not see this message continue with 9.1.3
Solution:
Search internet or other computers for the missing windows system file
MSWINSCK.OCX”,
Download and save that file into your PC under any folder
Copy the file into Windows System32 folder
C:/Windows/System32/
Click the executable file “Remote_ctr_V1.2.exe” again
1.1.3 Setting IP address of PIM31
Go to the Control Panel of the PIM31’s desktop screen and open the
Network Connections” icon.
Right click the “Local Area Connection” icon and open the properties window.
Select the “Internet Protocol (TCP/IP)” from the list and enter the IP address in
Przeglądanie stron 0
1 2 3 4 5

Podsumowanie treści

Strona 1

PIM31 Remote Setup and Operational Procedures 1 Remote Application and TCP/IP Setup PIM31 Remote Control Panel is the software to contr

Strona 2

input field.  Check “Use the following IP address”  Enter IP Address: 192.168.0.10 (for example) (The last number can be any nu

Strona 3

1.1.6 Check the network connection status of PIM31 and PC The network connection status for both PIM31 and the PC can be verified by

Strona 4

1.2 Using PIM31 Remote Application: Before using the remote application the following default settings for both IP address and port nu

Strona 5

1.2.2 List of remote commands Below are the lists of remote commands which can be executed remotely either by using Telnet or HyperT

Komentarze do niniejszej Instrukcji

Brak uwag